ECP — European Compliance Platform European Compliance Platform
EMC Testing Lab

Find an Accredited EMC Testing Laboratory

Describe your product, the applicable directive and the EMC standards you need tested — ECP matches your request to accredited laboratories with the right test capability and available slots.

Not sure this is the only thing you need? Build your full compliance roadmap →

When is EMC testing required for CE marking?

Electromagnetic Compatibility (EMC) testing is required for virtually all electrical and electronic products placed on the EU market. The EMC Directive 2014/30/EU applies broadly — it covers equipment that can cause electromagnetic disturbance or be affected by it. Most products with electronic circuits or mains connections need EMC testing as part of their CE marking conformity assessment.

Additional EMC requirements apply under the Radio Equipment Directive (RED), Low Voltage Directive (LVD), and sector-specific regulations such as medical devices (MDR/IVDR) and machinery. The applicable standards and test scope depend on your product category and the directives it falls under.

What EMC testing typically covers

Test TypeTypical Standards
Radiated emissionsEN 55032, EN 55011, EN 55014, CISPR 32
Conducted emissionsEN 55032, CISPR 32 (mains port)
Harmonics & flickerEN 61000-3-2, EN 61000-3-3
ESD immunityEN 61000-4-2
Radiated RF immunityEN 61000-4-3
EFT/Burst immunityEN 61000-4-4
Surge immunityEN 61000-4-5
Conducted RF immunityEN 61000-4-6
Voltage dips & interruptionsEN 61000-4-11

Self-declaration or Notified Body?

Under the EMC Directive the manufacturer chooses the route. Most products use internal production control (Annex II, Module A): you carry out the EMC assessment, usually by applying harmonised standards, keep the technical documentation and sign the EU Declaration of Conformity yourself. EU-type examination by a Notified Body (Annex III, Module B + C) is optional. Manufacturers choose it when no suitable harmonised standard exists, when they cannot apply the standards in full, or when a customer wants an independent certificate.

Fixed installations, such as a factory production line built on site, do not carry CE marking or a Declaration of Conformity, but they must still meet the essential requirements and be installed following good engineering practice.

Which emissions standard applies to your product

Product typeTypical emissions standard
IT, audio, video and multimedia equipmentEN 55032
Industrial, scientific and medical (ISM) equipmentEN 55011
Household appliances, power toolsEN 55014-1 (immunity: EN 55014-2)
Lighting equipmentEN 55015
No product-family standardGeneric standards EN IEC 61000-6-3 (residential) or EN IEC 61000-6-4 (industrial)

The intended environment matters: equipment for residential use must meet stricter emission limits (Class B) than equipment used only in industrial locations (Class A). Products with radio functions fall under the Radio Equipment Directive instead, where EMC is tested to the EN 301 489 series.

What to prepare before you contact a lab

  • A product description with the intended environment (residential, commercial, industrial)
  • All ports: mains, DC, signal, data and telecom lines, with maximum cable lengths
  • Operating modes, including the worst-case mode for emissions
  • Representative samples, accessories and any support equipment the product needs to run
  • Existing reports for components or earlier versions, and results of any pre-compliance scans

A pre-compliance scan before the formal test is the cheapest way to catch emission problems while PCB and enclosure changes are still easy. Many labs offer it as a short, separately priced session.

How to choose an EMC lab

  • Accreditation scope. Check that the lab's ISO/IEC 17025 accreditation lists the exact standards you need, in the current versions.
  • Test site. Large or heavy products need a lab with a large chamber or the option of on-site testing.
  • Combined scope. If you also need electrical safety (LVD) or radio testing, one lab covering all of them simplifies the technical file.

How ECP matching works

Describe your product, the applicable directive (EMC, RED, LVD, MDR, other), the specific EN standards you need tested, sample readiness and your target timeline. ECP routes your request to accredited EMC laboratories that cover your test scope.

You receive lab responses with scope confirmation, test cost estimates, typical lead times and next steps — without hunting for contacts or waiting for generic inquiry responses.

Send your request to accredited labs free →

Testing is one stage of CE marking — see how it fits with Notified Body assessment and EU representation: ECP for CE Marking — the full route →

Frequently Asked Questions

When is EMC testing required for CE marking?
Electromagnetic Compatibility (EMC) testing is required for virtually all electrical and electronic products placed on the EU market under EMC Directive 2014/30/EU. Additional EMC requirements apply under the Radio Equipment Directive (RED), Low Voltage Directive (LVD), and sector-specific regulations such as MDR and IVDR. The applicable standards and test scope depend on your product category and the directives it falls under.
What does EMC testing cover?
EMC testing typically covers radiated and conducted emissions (EN 55032, CISPR 32), harmonics and flicker (EN 61000-3-2, EN 61000-3-3), ESD immunity (EN 61000-4-2), radiated RF immunity (EN 61000-4-3), EFT/Burst immunity (EN 61000-4-4), surge immunity (EN 61000-4-5), conducted RF immunity (EN 61000-4-6), and voltage dips and interruptions (EN 61000-4-11). The specific tests required depend on your product category and applicable directive.
Do I need an accredited lab for EMC testing?
For CE marking, testing in an ILAC-accredited laboratory is the standard approach and is required for Notified Body conformity routes. For self-declaration (EU Declaration of Conformity), accredited test reports are strongly recommended and are typically expected by market surveillance authorities. Accredited labs issue internationally recognized reports.
How does ECP help find an EMC testing lab?
Describe your product, the applicable directive (EMC, RED, LVD, MDR, or other), the specific EN standards you need tested, sample readiness and your target timeline. ECP routes your request to accredited EMC laboratories that cover your test scope. You receive lab responses with scope confirmation, test cost estimates, typical lead times and next steps.
↩